TLC Series
The new three-phase string high-power photovoltaic inverters from UGOOD are widely used in commercial and industrial rooftops, as well as large-scale distributed and poverty alleviation power station system solutions. Featuring 8-10 MPPT channels and supporting up to 150% overmatching, along with an efficient control algorithm achieving a maximum efficiency of 98.9%, they significantly enhance power station profitability.
Flexible design
◆ Multi-communication interface: RS485, GPRS(optional), Wifi(optional) DC breaker, easy to maintain and safe to use
◆ Integrated functions of combiner box& DC lightning protection, reduce system cost for users
Efficient conversion
◆ Transformerless,max. efficiency is up to 98.9%;
◆ Euro. efficiency is up to 98.2%
◆ Total current THD <2%
◆ Three-level SVPWM control technology, increase DC voltage utilization
Grid friendly
◆ LVRT HVRT function
◆ Adjustable reactive power, power factor from 0.8 leading to 0.8 lagging
◆ Active and passive anti-islanding protection
◆ Continuously adjustable active power (0-100%) function
Excellent qualities
◆ CQC Gold Sun Certification, TUV Certification
◆ SAA Certification, CE Certification
Model Name | 80KTLC | 90KTLC | 100KTLC | 110KTLC | 125KTLC |
Input | |||||
Max.DC input power | 120KW | 135KW | 150KW | 165KW | 187.5KW |
Max.DC input voltage | 1100V | ||||
Max.DC input current | 30A*8 | 30A*9 | 30A*10 | 30A*10 | 30A*10 |
MPPT voltage range | 200-1000V | ||||
Recommended MPP operating voltage | 600V | ||||
No.of MPPT | 8 | 9 | 10 | 10 | 10 |
Max.no.of strings per MPPT | 2 | ||||
Output | |||||
Rated output power | 80KW | 90KW | 100KW | 110KW | 125KW |
Max.output power | 88KVA | 99KVA | 110KVA | 121KVA | 137.5KVA |
Max.output current | 127A | 142.9A | 158.8A | 174.6A | 199.3A |
Rated grid voltage | 400V | ||||
Grid voltage range | 310~480Vac | ||||
Rated grid frequency | 50Hz/60Hz | ||||
Grid frequency range | 45~55Hz/55~65Hz | ||||
THD | <2%(Under the rated power) | ||||
Power factor | >0.99(Under the rated power)/Adjustable range:0.8 leading~0.8 lagging | ||||
DC current injection | <0.5%(Under the rated power) | ||||
System data | |||||
Max.efficiency | 98.60% | 98.60% | 98.70% | 98.70% | 98.90% |
Euro.efficiency | 98.10% | 98.10% | 98.10% | 98.10% | 98.20% |
Humidity range | 0-100%non-condensing | ||||
Cooling type | Intelligent forced air cooling | ||||
Temperature range | -25~+60 C | ||||
Power consumption at night | <1W | ||||
Max.working altitude | 4000m | ||||
Display | LED/LCD/(optional) | ||||
Communication interface | Wifi/RS485/GPRS(optional) | ||||
Protection | |||||
DC reverse-polarity protection | Yes | ||||
Short circuit protection | Yes | ||||
Output over current protection | Yes | ||||
Output over voltage protection | Yes | ||||
Insulation resistance monitoring | Yes | ||||
Residual current detection | Yes | ||||
Surge protection | Yes | ||||
Grid monitoring | Yes | ||||
Islanding protection | Yes | ||||
Temperature protection | Yes | ||||
Integrated DC switch | Yes | ||||
Mechanical data | |||||
Dimensions (WxHxD) | 1050x620x333mm | ||||
Weight | 85kg | ||||
Protection class | IP66 | ||||
Standard | |||||
Grid-connected standard | NB/T 32004-2018;IEC61727 | ||||
Safety standard | NB/T 32004-2018;IEC 62109-1/2 | ||||
Electromagnetic compatibility | IEC61000-6-2/4 | ||||